Steam Boilers
Steam boiler services at PWS
We provide comprehensive steam boiler water treatment services to enhance efficiency, prevent corrosion, and extend the life of boiler systems.
Our process
BS 2486 is a British Standard that provides recommendations for the treatment of water in steam boilers and water heating systems. Proper water treatment is crucial in these systems to prevent scale, corrosion, and fouling, which can lead to inefficiencies, system failures, and safety hazards. Below are the key services provided under BS 2486 for water treatment in steam boilers. By adhering to BS 2486 standards, organizations can ensure their steam boilers operate efficiently, safely, and reliably, minimizing downtime, reducing energy costs, and extending the life of the equipment.
Water Quality Analysis
Initial Water Testing: Source Water Analysis and Feedwater and Boiler Water Analysis
Chemical Treatment Programmes
Scale and Corrosion Inhibition: Anti-Scaling Agents and Corrosion Inhibitors.
Oxygen Scavenging: Oxygen Scavengers.
pH Control: Alkalinity Adjustments
Boiler Blowdown Management
Blowdown Optimisation: Manual and Automatic Blowdown Systems and Blowdown Rate Calculation
Condensate Treatment
Condensate Return Line Protection: Corrosion Control in Condensate Systems and Monitoring and Treatment
System Monitoring and Control
Continuous Monitoring: Online Monitoring Systems and Data Logging and Analysis
Cleaning and Maintenance
Descaling and Cleaning: Chemical Cleaning and Mechanical Cleaning
Consultancy and Training
Custom Treatment Plans: Troubleshooting and Problem Solving and Training and Education
Documentation and Compliance
Maintenance Logs
Benefits of steam boiler servicing
The services provided under BS 2486 for water treatment in steam boilers offer numerous benefits, which are critical to the efficient and safe operation of these systems. Here are the key benefits:
Reduced Operational Costs
Reduces operational costs by decreasing the volume of water purchased from utility providers
Potential Penalties
Minimises potential penalties and fees associated with wastewater discharge and environmental compliance.
Local Water Resources
Reduces the demand on local water resources, which is crucial in regions facing water scarcity.
Environmental Benefits
Reduces operational costs by decreasing the volume of water purchased from utility providers
Sustainability
Enhances the site’s long-term sustainability by integrating water conservation into its core operational practices. Supports corporate social responsibility goals by demonstrating commitment to sustainable resource management.
Lower maintenance costs
Newer plants are designed with maintenance in mind, which can result in lower maintenance costs and less frequent downtime for repair.
Consultancy services
Risk assessment and management
Conducting risk assessments and Legionella control plan
Water treatment and quality control
Chemical treatment and monitoring water quality
Emergency Response Planning
Incident Response Procedures
System monitoring and control
Automation and monitoring systems and record keeping and documentation
Training and Competency
Staff training
Cleaning and maintenance
System cleaning and inspection and maintenance
Audit and Compliance
Internal and External Audits
Looking for more information?
Discuss the benefits
Maintaining cooling towers according to ACOP L8 guidelines offers several important benefits, particularly in terms of health, safety, operational efficiency, and compliance. Here are some of the key benefits:
Health & Safety
Prevention of Legionnaires’ Disease, reduced risk of Legionella, public and occupational health protection
Operational Efficiency
Improved system performance: optimal heat exchange and consistent water quality. Reduced downtime and maintenance costs: fewer breakdowns and extended equipment life.
Compliance and Legal Protection
Regulatory compliance: adherence to legal requirements and preparedness for audits
Environmental and Economic Benefits
Efficient resource use: water and energy conservation. Cost Savings: lower operating costs and avoidance of outbreak costs
Risk Management and Business Continuity
Risk Mitigation: comprehensive risk management and business continuity
Reputation and Stakeholder Confidence
Demonstrated Commitment to Safety: enhanced reputation and stakeholder confidence
Cooling tower maintenance
Overall, the benefits of maintaining cooling towers according to ACOP L8 are extensive and multifaceted, encompassing health and safety, operational efficiency, regulatory compliance, and economic advantages. These benefits underscore the importance of diligent cooling tower maintenance and water treatment in managing the risks associated with these systems.
News
We work in
Education
Healthcare
Industrial
Local authority
Facilities management
Commercial
Historical
Housing
Hotel & leisure
Can’t see your industry?
Looking for a tailored package?
Speak to a member of the team today to get a custom quote for your specific requirements
Your questions answered
Still have questions? Contact us for more information.